CIMPLICITY HMI 7.5 SIM 11
授权形式: 免费版
更新时间: 2009-05-03 22:59:32
软件语言: 英文
软件平台: Win2000/WinXP/Win2003
软件类别: 国外软件
文件大小: 17MB
评论等级: ★★★☆☆
下载次数: 0(今日:,本周:,本月:

软件简介

Type File Name Date Posted Size Description
  CIM_7.5_SIM_11.zip  04/08/09  16.5MB  CIMPLICITY 7.5 SIM 11 
Product Version Module
HMI/SCADA - CIMPLICITY 7.5 All

Name : CIMPLICITY 7.5 SIM 11
Version : 7.5
Brief Description

Proficy HMI/SCADA - CIMPLICITY 7.5 SIM 11

NOTE: This SIM is cumulative with Proficy HMI/SCADA - CIMPLICITY 7.5 SIM 10 and prior.


Alarm Viewer Control - #173858  - 1-761634665, 1-766648291, 1-764263621, 1-765451043

After the application of 7.5 SIM 10, the Alarm Viewer Active X control had the following issues:

- The ActiveX Event was no longer available.
- The methods for the Alarm Viewer were no longer available to invoke via procedure.
- The object methods were no longer accessible via script.
 
- The ActiveX Event and the Alarm Viewer OCX methods can now be accessed.


Alarm Viewer OCX - #173873 - 1-743926884

All open instances of CimView would close under the following conditions.

- A point that had an associated screen was in an alarm state.
- The alarm displayed in an Alarm Viewer Control on a CimView screen.
- The alarm's CimView screen button was clicked in the Alarm Viewer control.

Result: All open CimView instances were terminated; the associated screen opened in a new CimView window.

Note: The screen is associated with a point on the View tab in its Point Properties dialog box.
 
A point alarm's associated screen can now be opened in an Alarm Viewer OCX's CimView screen without affecting other open CimView screens.
 

Properties Dialog Box - #173289 - 1-667628193

When a Properties dialog box was closed in CimEdit or CimView, the focus did not return to the CimEdit or CimView screen.

Note: This issue occurred with CIMPLICITY v7.5 SIM 7 or higher and with only the French  Windows XP operating system; it is not reproducible on other operating systems.
 
When a Properties dialog box is now closed on a CimEdit or CimView screen, the focus now goes back to the screen.
 
 
Trend Object - #173289 - 1-676958191

When a Trend chart was running on a CimView screen, if its Properties dialog box was opened, the Trend chart would close when the Properties dialog box was closed.

Note: This issue occurred with CIMPLICITY v7.5 SIM 3 and higher.

The Trend chart now remains open during runtime if its Properties dialog box is opened and closed.


Honeywell IPC620 - #173668 - 1-662536201

Honeywell IPC620 diagnostics would randomly be enabled or disabled

Diagnostic messages may now be selectively enabled or disabled in the Honeywell device communication interfaces.

When enabled, the diagnostics are directed to the .err file located in the project's log directory.

The following global parameters are now available to enable of disable diagnostics.
 
Project Global Parameter: HWABC_DEBUG
 
This enables or disables the diagnostics for all device communication interfaces that use the Honeywell IPC620 protocol.
 
Values:

Y - Enables the diagnostics.
N - Disables the diagnostics.
 
Default - N
 
Project Global Parameter: <PORT>_DEBUG

Where <PORT> is the PORT name in the CIMPLICITY Project.
 
Enables or disables diagnostics for a selected port that uses the Honeywell IPC620 protocol.
 
Values:

Y - Enables the diagnostics.
N - Disables the diagnostics.
 
Default - N

Note: If both <PORT>_DEBUG and HWABC_DEBUG are defined. <PORT>_DEBUG has precedence.
 

CNC Alarm Process - #173740 - 1-707819814

If a non-CNC device was configured in a CNC project, the CNC_ALM process would fail to start properly and would consume CPU resources; this prevented the full project startup.
 
The CNC_ALM process now starts normally regardless of what types of devices are configured in the project.

 
Point Cross Reference - #173478 - 1-648619212

Point Cross Reference could continue to display points that no longer existed even if the point and all corresponding screen animations were deleted.
 
Point Cross Reference no longer displays points that have be completely deleted from the project.

 
Historian Integration - #173613 - 1-704027355, 1-690437527

When a Server Redundant CIMPLICITY project is configured to log to a Historian database via either the OPC Data or OPC AE interfaces, an issue existed where the collectors would be incorrectly auto-configured in Historian.

This could result in a situation where the collectors would fail to stop on a Server Redundant failover.
 
Historian collectors now stop on a Server Redundant failover.
 

Historian Integration - #173462 - 1-695715391

When a server redundant CIMPLICITY project logged to a Historian database via the OPC interface, an invalid logging definition could occur where the OPC point could be referring to a node name instead of a project name.

This would result in a Failed Checking Status error in the project status logs. This error could occur on either the primary or the secondary in the Server Redundant pair.

When a server redundant CIMPLICITY project logs to Historian via the OPC interface there will no longer be a Failed Checking Status error in the cor_recstat log, and the logging will be done correctly.
 

Tracker PRT_UI - #170081 - 1-531271937

PRT_UI would stop being operational when the Refresh Region List button was clicked.

PRT_UI now refreshes the region list and continues to operate when the Refresh Region List button is clicked.


Tracker - #169033 - 1-482519672

An error message, "Item no longer in local project", did not identify the item.

The error message,  "Item no longer in local project," now displays the item ID.


Tracker - #169643 - 1-477887053

When  an association was deleted from a Tracker Item, that association was not removed in the related_items table in the Tracker Attribute Database (TADB).

When an association is now deleted from a Tracker Item, that  association is removed in the related_items table in the Tracker Attribute Database.


Tracker - #168590 - 1-466060758

When a new Tracker project was configured, and the PRT Service Configuration dialog box was first opened, It did not populate with the already created alarms.

When a new Tracker project is configured, existing alarms now populate, as default alarms, the new service that is being created.


Tracker PRT_CNT - #169748 - 1-466007100

The Tracker Graphics Display (PRT_CNT) that was used for Tracker display points had an invalid default refresh rate.

The Tracker Graphics Display now has a valid default refresh rate.


Tracker Scripting - #169645 - 1-421962602

When attempting to remove a record from a Group Attribute table for a TADB item, if the table has a column that is defined as a unique and datetime, then the attempt to remove the record using TrkRecords.Remove oTrkRecord.ID it will fail and throw an error.
 
When attempting to remove the record using TrkRecords.Remove oTrkRecord.ID it will succeed and will no longer throw an error.

----------------------------------------